PW and WFI systems, from feed water to the last point of use.
AQCOT is a Korean engineering team specialized in purified water and water for injection for pharmaceutical and biopharmaceutical manufacturing. We maintain, troubleshoot and upgrade generation, storage and distribution systems, and help keep them qualified.
Two grades of water, two sets of rules.
Purified water and water for injection share equipment, people and often a plant room. They do not share limits, generation methods or the consequences of getting them wrong.
| Attribute | Purified water (PW) | Water for injection (WFI) |
|---|---|---|
| Used for | Non-parenteral products, equipment cleaning, feed to WFI and clean steam generators | Parenteral products, final rinse of product-contact equipment, media and buffer preparation |
| Typically made by | Pretreatment, reverse osmosis and electrodeionization | Distillation in multi-effect or vapor compression stills, or membrane systems where the pharmacopoeia allows |
| Stored and distributed | Ambient or hot loops with periodic sanitization by heat, ozone or UV | Hot loops, commonly around 80 °C, or cold loops with frequent sanitization |
| Extra attribute | None beyond conductivity, TOC and microbial count | Bacterial endotoxins, with a much tighter microbial limit |
The numbers we keep you inside
Every loop we look after is judged against these attributes. Values shown are USP; Ph. Eur. and KP differ on some, and we work to the monograph your site is registered under.
| Attribute | PW | WFI |
|---|---|---|
| ConductivityStage 1, at 25 °C | PW≤ 1.3 µS/cm | WFI≤ 1.3 µS/cm |
| Total organic carbon | PW≤ 500 ppb | WFI≤ 500 ppb |
| Microbial action levelGuidance in USP <1231> | PW100 CFU/mL | WFI10 CFU/100 mL |
| Bacterial endotoxins | PWNot specified | WFI< 0.25 EU/mL |
Equipment we work on
Purified water generation
Multimedia and carbon filters, softeners, chemical dosing, single and double-pass RO, EDI and UF.
WFI generation
Multi-effect and vapor compression stills, and membrane-based WFI systems.
Storage and distribution
Tanks, vent filters, loop pumps, heat exchangers, sanitary valves, online conductivity and TOC, ozone and UV.
What we're called in for
Most water problems show up first as a number drifting on a trend or a failed sample. Finding the cause quickly is where experience counts.
| Symptom | Usual causes | What we do |
|---|---|---|
| Conductivity creeping up | Aging RO membranes, exhausted EDI or softener, CO₂ breakthrough | Trend review, membrane and EDI performance tests, cleaning or replacement plan |
| TOC excursions | Feed water changes, carbon bed or UV issues, contamination after maintenance | Sampling across the train to locate the source, then corrective work and verification |
| Microbial counts at one point of use | Dead legs, valve or hose issues, sampling practice | Point-of-use walkdown, valve and drop inspection, targeted sanitization and resampling plan |
| Rouge in hot WFI loops | Iron oxide build-up on stainless surfaces over years of hot operation | Inspection, derouging and repassivation planned around shutdowns |
| Loop temperature or return flow too low | Pump wear, heat exchanger fouling, demand above design | Hydraulic check, component service, capacity assessment |
Services
Delivered on site by engineers who commission and service PW and WFI systems in Korea.
-
Preventive maintenance
Planned service of generation and distribution equipment, timed around production and requalification windows.
-
Troubleshooting and emergency response
On-site diagnosis of quality excursions, alarms and equipment faults, with a clear written account of cause and fix.
-
Sanitization and passivation
Thermal, ozone and chemical sanitization support, derouging and repassivation of stainless steel systems.
-
Spare parts
Critical spares lists and stocking plans for membranes, EDI modules, pumps, valves, gaskets and instruments.
-
Upgrades and capacity
Control system replacement, added generation or storage capacity, new loops and points of use.
-
Qualification support
SAT, IQ/OQ execution support, PQ sampling plans and change control input after work on the system.
From design review to year ten
One team follows the system from its first drawings through qualification and years of operation.
Design review
Demand profile, points of use, feed water and loop hydraulics.
FAT
Factory test witness and document review before shipment.
Installation and SAT
Site supervision, commissioning and site acceptance testing.
Qualification
IQ/OQ support and PQ sampling through each phase.
Operation and upgrades
Maintenance, excursion response and capacity changes.
Talk to a water engineer
Tell us which system it is, what you are seeing and how soon you need help. An engineer will reply with next steps.